SBW DBW Three-phase and Single-phase AC Manostats

Purpose:
SBW DBW three-phase and single-phase AC manostats are high-power regulated power supply characterized by contact voltage regulating and automatic compensation. When voltage of electric network fluctuates or load current shifts, these manostats can output stable voltage automatically to guarantee failure free operation of electric appliances.
Application:
Power supply of small-sized factories
Power supply, post and communications of industrial workshops and departments of large and medium sizes
Supporting important equipment and individual machines

Performance of Three-phase

·Input:Three-phase four-wire system Phase Voltage 175-250V Line Voltage 304-456V
·Output:Three-phase four-wire system Phase Voltage210-230V Line Voltage 361-399V
·Leading in and out terminals (phase conductors and neutral conductor)can bear 50Hz line frequency and 200V sine voltage of bracket for one minute
·Efficiency:When manostat works under normal power, the efficiency is higher than 98%.
·Additional waveform distortion of output voltage <1%

Performance of Single-phase


·Input Voltage:176V-264V 130V-260V
·Output Voltage:220V±5% Line Voltage (can be set)
·Withstand Voltage:2000V, no breakdown within one minute.
·Main Technical Traits:Updated international compensation techniques are used. Manual and automatic control modes are available. No guard is needed for regulated voltage of electric supply; free switch without break; high precision for voltage regulating; wide range; no waveform distortion; overvoltage protection; delayed automatic recovery; automatic switch off delayed failure adjustment; three-phase imbalance; sound and flash alarm.

DBW Standard Power
(KVA)
3 5 10 20 30 50 100 150 200 250 300
Output Current (A) 14 23 46 91 137 228 455 681 910 1136 1364

SBW Standard Power (KVA) 20 30 50 100 180 225 320 400 500 600 650 700 800 1000 1200 1600 2000
Output Current (A) 31 46 76 152 273 342 487 608 760 910 990 1065 1216 1520 1825 2434 3040

 
 
*SVC Series High-precision Full Automatic Three-phase AC Manostats*
 
Application:

·Computer·Testing Equipment·Lighting System·Security Alarm System
·Radial Equipment·Communication System·Medical Equipment·Color Picture Processor
·Numerical Control Machine Tool·Industrial Automation Equipment·Testing Equipment·Hi-Fi Equipment
 

SVC Series High-precision Full Automatic Three-phase AC Manostats

SVC/Three-phase Performance:

Input Voltage Three-phase 280V-430V
Output Voltage Three-phase 380V±3%
Number of Phases Three-phase four-wire system
Frequency 50HZ/60HZ
Adjustment Time <1 s (input voltage shift: 10%)
Efficiency >95%
Ambient Temperature -5℃~+40℃
Relative Humidity <95%
Waveform Distortion Free from additional waveform distortion
Insulation Resistance >5MΩ
Withstand Voltage in accordance with stipulated standards

 
 
 
Application:

·Computer·Testing Equipment·Lighting System·Security Alarm System
·Radial Equipment·Communication System·Medical Equipment·Color Picture Processor
·Numerical Control Machine Tool·Industrial Automation Equipment·Testing Equipment·Hi-Fi Equipment
 
 
SVC Series High-precision Full Automatic Three-phase AC Manostats
Performance:

Input Voltage 160V-250V 70V-130V
Output Voltage 220V±3% with 110V±3%
Number of Phases Single Phase
Frequency 50HZ/60HZ
Adjustment Time <1 s (input voltage shift: 10%)
Efficiency >90%
Ambient Temperature -5℃~+40℃
Relative Humidity <95%
Waveform Distortion Free from additional waveform distortion
Insulation Resistance >5MΩ
 

 
 

*SJW-WB DJW-WB Series Microcomputer Control Noncontact Compensation Type Electric Manostats
*
 
Application:
·Broadcasting and TV System·Industrial Equipment·Computer System
·Microwave Communications without Guard·Industrial Computer ·Power Supply
 

SJW-WB DJW-WB Series Microcomputer Control Noncontact Compensation Type Electric Manostats

Instruction:
SJW-WB DJW-WB single-phase and three-phase series of high-power full automatic compensation type manostats embody up-to-date winding compensation, noncontact switch and microcomputer control AC voltage regulating technology, so they are characterized by high efficiency, energy saving, rapid adjustment, three-phase automatic balance, no mechanical failure or abrasion of carbon brush. Moreover, they have delay function, overlaod protection, undervoltage alarm and so on.

1. Updated combination winding compensation technology is used, so there is little waveform distortion.
2.Onechip control combinations brake tube is used to switch combinations for proper compensative regulation. Instant noncontact adjustment is realized. The instantaneous overload is high enough to fit for various loads.
3.SCM is used for subset control. They have functions of delayed startup, three-phase automatic balance adjustment, display, alarm and protection of loss of phase, overload and failure etc.

Technical Parameters:

Index\Specifications Three-phase SJW-WB
10-200KVA
Single-phase DJW-WB
3-60KVA
Range of Input Voltage ±20%~±30%(Optional)
Precision of Output Voltage ±2%~±5%(Optional)
Efficiency >95%
Power Factor of Load >±0.7
Response Time 0.1s-0.3s
Frequency 50~60HZ
Instantaneous Overload 1.5~2 times of rated current

 
 

*JSW Series High-precision AC Cleaning Manostats*
 

JSW Series High-precision AC Cleaning Manostats

·Novel and handsome look; technical structure is well designed
·Wide range of input voltage; high precision
·Restrain noise of electric network and disturbance of overshoot effectively
·Short response time; high reliability; high stability
Precision cleaning AC manostat is designed by our company according to Cusparia's theory of "sine energy distribution" combined with high-efficiency broadband filter network. This series of power supply is characterized by wide range of voltage regulating, high precision and short response time. Furthermore, it can restrain noise of electric network and disturbance of overshoot effectively. Also it has features of high reliability, stable performance, handsome style and complete varieties. There are many different fingers and gauge outfits for users' options. Single-phase and three-phase power supply, normal type and lightning protection type are available to meet different requirements of different users. They are widely used in industrial enterprises, communications, transportations, colleges, universities, medical treatment, broadcasting, stations, hotels, research institutes and governmental agencies etc. Especially, they are suitable for microcomputer network, broadcasting equipment, signal system, testing equipment, imported equipment and automatic pipeline etc. Also they are fit for terminal users of low-voltage large-amplitude of fluctuation hypothecary eletric network.

Performance and Specifications:
  Single Phase Three Phase
Rated Power 1KVA 2KVA 3KVA 5KVA 120KVA 15KVA 20KVA 3KVA 6KVA 10KVA 15KVA 20KVA 30KVA 50KVA
Input Voltage

185V-250V
(Spread 165V-250V)

Phase Voltage 180V-250V
Line Voltage 310V-450V
Output Voltage 220V Phase Voltage 220V±1%
Line Voltage 380V±2%
Source Voltage Effect 198V-242V: <±1%
165V-250V: <±2%
Phase Voltage <±1%
Line Voltage <±2%
Load Effect 198V-242V: <±1%
165V-250V: <±2%
<±2%
Additional Waveform Distortion ≤±3% <±5%
Response Time 20ms-100ms 20ms-100ms
Peak Absorption Input 1000V/3us Output≤5V Input 1000V/3us Output≤5V
Efficiency ≥90%(Below 2KVA)
≥95%(Below 3KVA)
≥92%
Audio Frequency Noise ≤55bB(Below 2KVA)
≤60bB(Below 3KVA)
≤60dB
Output Voltage Protection Value 250V±5V

Phase Voltage 250V±5V
Line Voltage 435V±10V

Operational Environment Humidity -10℃~+40℃ Humidity -10℃~+40℃
Degree of Unbalance of Output of Three-phase Voltage ------- ≤3%

 
 

*Transformer Series JBK BKC BK JMB SBK QIB
*
 

Transformer Series JBK BKC BK JMB SBK QIB

Purpose
JBK, BKC, BK series of control transformers are used for 50-60Hz AC circuit, normal electronic control switches of electronics industry, factories, machine tools and equipment. Also they are applied as power supply for safe lighting and indicator light.

 
 
Insolating Transformer

Summary:
This series of transformers are indoor air self-cooling type, which are applied to low-voltage regulating and power supply insulation of AC 50Hz-60Hz.


 
 contract us